Created on 12/14/2016
c
2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 1 of 2
MODEL
RVGE
Ventable, fast-acting, pilot operated, balanced piston relief valve
SERIES 3 / CAPACITY: 240 L/min. / CAVITY: T-17A
Fast-acting, ventable, pilot-operated, balanced piston relief cartridges are normally closed pressure regulating
valves. When the pressure at the inlet (port 1) reaches the valve setting, the valve starts to open to tank (port 2),
throttling flow to regulate the pressure. They provide a vent port (port 3) that connects between the main piston and
pilot stage to provide for remote control by other pilot or 2-way valves. These valves have low pressure rise vs. flow
and are very fast.
TECHNICAL DATA
Cavity T-17A
Series 3
Capacity 240 L/min.
Factory Pressure Settings Established at 15 L/min.
Maximum Operating Pressure 350 bar
Control Pilot Flow 0,25 - 0,33 L/min.
Response Time - Typical 2 ms
Maximum Valve Leakage at 110 SUS (24 cSt) 65 cc/min.@70 bar
Adjustment - Number of Clockwise Turns to Increase Setting 5
Valve Hex Size 31,8 mm
Valve Installation Torque 203 - 217 Nm
Adjustment Screw Internal Hex Size 4 mm
Locknut Hex Size 15 mm
Locknut Torque 9 - 10 Nm
Seal kit - Cartridge Buna: 990017007
Seal kit - Cartridge Polyurethane: 990017002
Seal kit - Cartridge Viton: 990017006
Model Weight 0.62 kg.
(L)CONTROL
L Standard Screw Adjustment
(A)ADJUSTMENT RANGE
A 100 - 3000 psi (7 - 210 bar), 1000 psi
(N)SEAL MATERIAL
N Buna-N
snhy.com/RVGE
Model Code Example: RVGELANCONFIGURATION OPTIONS
Created on 12/14/2016
c
2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 2 of 2
(70 bar) Standard Setting
B 50 - 1500 psi (3,5 - 105 bar), 1000 psi
(70 bar) Standard Setting
D 25 - 800 psi (1,7 - 55 bar), 400 psi (28
bar) Standard Setting
W 150 - 4500 psi (10,5 - 315 bar), 1000
psi (70 bar) Standard Setting
V Viton
TECHNICAL FEATURES
A remote pilot relief on port 3 (vent) will control the valve below its own setting.
Will accept maximum pressure at port 2; suitable for use in cross port relief circuits. If used in cross port relief circuits, consider spool leakage.
Main stage orifice is protected by a 150 micron stainless steel screen.
Not suitable for use in load holding applications due to spool leakage.
Back pressure on the tank port (port 2) is directly additive to the valve setting at a 1:1 ratio.
Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge
machining variations.
PERFORMANCE CURVES